Asco Parcel Under 80 lbs +$250
Asco Parcel Under 80 lbs +$250
ASCO 185 Series Automatic Transfer Switch NON-SE RATED 100A NEMA 1
By PGA LLC AdmiN | |
ASCO Automatic Transfer Switch Manufactured by Schneider Electric.
With an ATS, you are protected 24 hours a day, seven days a week.
When the utility power fails, the ATS automatically starts the generator set and
transfers the load once the generator has reached proper voltage and
frequency. This happens in a matter of seconds after the power failure occurs.
As soon as the utility power has been restored, the ATS will automatically switch the load
back and, after a time delay, shut down the engine generator.
UL 1008
Listed to UL 1008 standard for total system loads for automatic transfer switches.
Weekly Exerciser
          Exercises with or without load.
Withstand and Close-On Rating
Maximum of 10kA when used with circuit breakers.

Additional Information

ASCO Series 185 Series
Rating SE Rated, Non-SE Rated
Amperage 100 Amps
Voltage Output 240V
Current Limiting Fuses 200kA
Dimensions (WxDxH) 14.25" x 8.25" x 24"
 
ASCO 185 Series Automatic Transfer Switch NON-SE RATED 100A NEMA 3R
By PGA LLC AdmiN | |
ASCO Automatic Transfer Switch Manufactured by Schneider Electric.
With an ATS, you are protected 24 hours a day, seven days a week.
When the utility power fails, the ATS automatically starts the generator set and
transfers the load once the generator has reached proper voltage and
frequency. This happens in a matter of seconds after the power failure occurs.
As soon as the utility power has been restored, the ATS will automatically switch the load
back and, after a time delay, shut down the engine generator.
UL 1008
Listed to UL 1008 standard for total system loads for automatic transfer switches.
Weekly Exerciser
          Exercises with or without load.
Withstand and Close-On Rating
Maximum of 10kA when used with circuit breakers.

Additional Information

ASCO Series 185 Series
Rating SE Rated, Non-SE Rated
Amperage 100 Amps
Voltage Output 240V
Current Limiting Fuses 200kA
Dimensions (WxDxH) 14.25" x 8.25" x 24"
 
ASCO 185 Series Automatic Transfer Switch NON-SE RATED 200A NEMA 1
By PGA LLC AdmiN | |
ASCO Automatic Transfer Switch Manufactured by Schneider Electric.
With an ATS, you are protected 24 hours a day, seven days a week.
When the utility power fails, the ATS automatically starts the generator set and
transfers the load once the generator has reached proper voltage and
frequency. This happens in a matter of seconds after the power failure occurs.
As soon as the utility power has been restored, the ATS will automatically switch the load
back and, after a time delay, shut down the engine generator.
UL 1008
Listed to UL 1008 standard for total system loads for automatic transfer switches.
Weekly Exerciser
          Exercises with or without load.
Withstand and Close-On Rating
Maximum of 10kA when used with circuit breakers.

Additional Information

ASCO Series 185 Series
Rating SE Rated, Non-SE Rated
Amperage 200 Amps
Voltage Output 240V
Current Limiting Fuses 200kA
Dimensions (WxDxH) 14.25" x 8.25" x 24"
 
ASCO 185 Series Automatic Transfer Switch NON-SE RATED 200A NEMA 3R
By PGA LLC AdmiN | |
ASCO Automatic Transfer Switch Manufactured by Schneider Electric.
With an ATS, you are protected 24 hours a day, seven days a week.
When the utility power fails, the ATS automatically starts the generator set and
transfers the load once the generator has reached proper voltage and
frequency. This happens in a matter of seconds after the power failure occurs.
As soon as the utility power has been restored, the ATS will automatically switch the load
back and, after a time delay, shut down the engine generator.
UL 1008
Listed to UL 1008 standard for total system loads for automatic transfer switches.
Weekly Exerciser
          Exercises with or without load.
Withstand and Close-On Rating
Maximum of 10kA when used with circuit breakers.

Additional Information

ASCO Series 185 Series
Rating SE Rated, Non-SE Rated
Amperage 200 Amps
Voltage Output 240V
Current Limiting Fuses 200kA
Dimensions (WxDxH) 14.25" x 8.25" x 24"
 
ASCO 185 Series Automatic Transfer Switch NON-SE RATED 230A NEMA 1
By PGA LLC AdmiN | |
The ASCO 185 Series automatic transfer switch (ATS) are 2-wire control switches that are compatible with all 2-wire start systems from all manufacturers. The switch monitors incoming utility power. When the utility power fails it starts the generator and transfer the emergency load onto the generator. After the utility power is restored it will transfer the load back to the utility source, cool down the generator and then return to a standby mode. The ATS has an exercise circuit that tests the generator system every week. The automatic test feature can be set under load or under no load.
Amperage 230 Amps
Voltage Output 115-480V
Frame D
Current Limiting Fuses 480V Max. 100kA
Dimensions (WxHxD) NEMA 1: 18″ x 48″ x 13″ NEMA 3R, 4, 12: 18″ x 50.5″ x 14.33″
 
ASCO 185 Series Automatic Transfer Switch NON-SE RATED 230A NEMA 3R
By PGA LLC AdmiN | |
The ASCO 185 Series automatic transfer switch (ATS) are 2-wire control switches that are compatible with all 2-wire start systems from all manufacturers. The switch monitors incoming utility power. When the utility power fails it starts the generator and transfer the emergency load onto the generator. After the utility power is restored it will transfer the load back to the utility source, cool down the generator and then return to a standby mode. The ATS has an exercise circuit that tests the generator system every week. The automatic test feature can be set under load or under no load.
Amperage 230 Amps
Voltage Output 115-480V
Frame D
Current Limiting Fuses 480V Max. 100kA
Dimensions (WxHxD) NEMA 1: 18″ x 48″ x 13″ NEMA 3R, 4, 12: 18″ x 50.5″ x 14.33″
 
ASCO 185 Series Automatic Transfer Switch NON-SE RATED 260A NEMA 1
By PGA LLC AdmiN | |
The ASCO 185 Series automatic transfer switch (ATS) are 2-wire control switches that are compatible with all 2-wire start systems from all manufacturers. The switch monitors incoming utility power. When the utility power fails it starts the generator and transfer the emergency load onto the generator. After the utility power is restored it will transfer the load back to the utility source, cool down the generator and then return to a standby mode. The ATS has an exercise circuit that tests the generator system every week. The automatic test feature can be set under load or under no load.
Amperage 260 Amps
Voltage Output 115-600V
Frame J
Current Limiting Fuses 480/600V Max. 200kA
Dimensions (WxHxD) NEMA 1: 24″ x 56″ x 14″ NEMA 3R, 4, 12: 24″ x 63″ x 18.2″
 
ASCO 185 Series Automatic Transfer Switch NON-SE RATED 260A NEMA 3R
By PGA LLC AdmiN | |
The ASCO 185 Series automatic transfer switch (ATS) are 2-wire control switches that are compatible with all 2-wire start systems from all manufacturers. The switch monitors incoming utility power. When the utility power fails it starts the generator and transfer the emergency load onto the generator. After the utility power is restored it will transfer the load back to the utility source, cool down the generator and then return to a standby mode. The ATS has an exercise circuit that tests the generator system every week. The automatic test feature can be set under load or under no load.
Amperage 260 Amps
Voltage Output 115-600V
Frame J
Current Limiting Fuses 480/600V Max. 200kA
Dimensions (WxHxD) NEMA 1: 24″ x 56″ x 14″ NEMA 3R, 4, 12: 24″ x 63″ x 18.2″
 
ASCO 185 Series Automatic Transfer Switch SE RATED 100A NEMA 1
By PGA LLC AdmiN | |
ASCO Automatic Transfer Switch Manufactured by Schneider Electric.
With an ATS, you are protected 24 hours a day, seven days a week.
When the utility power fails, the ATS automatically starts the generator set and
transfers the load once the generator has reached proper voltage and
frequency. This happens in a matter of seconds after the power failure occurs.
As soon as the utility power has been restored, the ATS will automatically switch the load
back and, after a time delay, shut down the engine generator.
UL 1008
Listed to UL 1008 standard for total system loads for automatic transfer switches.
Weekly Exerciser
          Exercises with or without load.
Withstand and Close-On Rating
Maximum of 10kA when used with circuit breakers.

Additional Information

ASCO Series 185 Series
Rating SE Rated, Non-SE Rated
Amperage 100 Amps
Voltage Output 240V
Current Limiting Fuses 200kA
Dimensions (WxDxH) 14.25" x 8.25" x 24"
 
ASCO 185 Series Automatic Transfer Switch SE RATED 100A NEMA 3R
By PGA LLC AdmiN | |
ASCO Automatic Transfer Switch Manufactured by Schneider Electric.
With an ATS, you are protected 24 hours a day, seven days a week.
When the utility power fails, the ATS automatically starts the generator set and
transfers the load once the generator has reached proper voltage and
frequency. This happens in a matter of seconds after the power failure occurs.
As soon as the utility power has been restored, the ATS will automatically switch the load
back and, after a time delay, shut down the engine generator.
UL 1008
Listed to UL 1008 standard for total system loads for automatic transfer switches.
Weekly Exerciser
          Exercises with or without load.
Withstand and Close-On Rating
Maximum of 10kA when used with circuit breakers.

Additional Information

ASCO Series 185 Series
Rating SE Rated, Non-SE Rated
Amperage 100 Amps
Voltage Output 240V
Current Limiting Fuses 200kA
Dimensions (WxDxH) 14.25" x 8.25" x 24"
 
ASCO 185 Series Automatic Transfer Switch SE RATED 200A NEMA 1
By PGA LLC AdmiN | |
ASCO Automatic Transfer Switch Manufactured by Schneider Electric.
With an ATS, you are protected 24 hours a day, seven days a week.
When the utility power fails, the ATS automatically starts the generator set and
transfers the load once the generator has reached proper voltage and
frequency. This happens in a matter of seconds after the power failure occurs.
As soon as the utility power has been restored, the ATS will automatically switch the load
back and, after a time delay, shut down the engine generator.
UL 1008
Listed to UL 1008 standard for total system loads for automatic transfer switches.
Weekly Exerciser
          Exercises with or without load.
Withstand and Close-On Rating
Maximum of 10kA when used with circuit breakers.

Additional Information

ASCO Series 185 Series
Rating SE Rated, Non-SE Rated
Amperage 200 Amps
Voltage Output 240V
Current Limiting Fuses 200kA
Dimensions (WxDxH) 14.25" x 8.25" x 24"
 
ASCO 185 Series Automatic Transfer Switch SE RATED 200A NEMA 3R
By PGA LLC AdmiN | |
ASCO Automatic Transfer Switch Manufactured by Schneider Electric.
With an ATS, you are protected 24 hours a day, seven days a week.
When the utility power fails, the ATS automatically starts the generator set and
transfers the load once the generator has reached proper voltage and
frequency. This happens in a matter of seconds after the power failure occurs.
As soon as the utility power has been restored, the ATS will automatically switch the load
back and, after a time delay, shut down the engine generator.
UL 1008
Listed to UL 1008 standard for total system loads for automatic transfer switches.
Weekly Exerciser
          Exercises with or without load.
Withstand and Close-On Rating
Maximum of 10kA when used with circuit breakers.

Additional Information

ASCO Series 185 Series
Rating SE Rated, Non-SE Rated
Amperage 200 Amps
Voltage Output 240V
Current Limiting Fuses 200kA
Dimensions (WxDxH) 14.25" x 8.25" x 24"
 
ASCO 300 Series Automatic Transfer Switch NON-SE RATED 2 Pole 1-PH 3-PH 104A NEMA 1
By PGA LLC AdmiN | |
ASCO Automatic Transfer Switch Manufactured by Schneider Electric.
With an ATS, you are protected 24 hours a day, seven days a week.
When the utility power fails, the ATS automatically starts the generator set and
transfers the load once the generator has reached proper voltage and
frequency. This happens in a matter of seconds after the power failure occurs.
As soon as the utility power has been restored, the ATS will automatically switch the load
back and, after a time delay, shut down the engine generator.
UL 1008
Listed to UL 1008 standard for total system loads for automatic transfer switches.
Meets NFPA 110
Meets NFPA 110 for Emergency and Standby Power Systems and the National Electrical Code Articles 700, 701 and 702.
True Double-Throw Operation
The inherently inter-locked, single solenoid design prevents connections to both
sources at the same time.
Series 300 Group G Controller
Easy-to-navigate 128×64  LCD display with keypad provides LED indicators for switch
position, source availability, not in auto mode, and alert condition.
The controller also includes test and time delay bypass soft keys.
Withstand and Close-On Rating
Maximum of 42kA when used with circuit breakers.
Designed to Fit Anywhere
The ASCO Automatic Transfer Switch, 300 series line represents the most compact design
of automatic power transfer switches in the industry. With space in electrical closets being
at a premium, the use of wall or floor mounted ASCO Transfer Switches assure designers
optimum utilization of space. All transfer switches through 2000 amperes are designed to
be completely front accessible; permitting the enclosures to be installed flush against the
wall while allowing installation of all power cabling and connections from the front of the
switch. Additionally, cable entrance plates are also standard on the 1600 and 2000 amperes
units to install optional side-mounted pull boxes for additional cable bending space.

Additional Information

Amperage 104 Amps
Voltage Output 115-600V
Frame D
Current Limiting Fuses 480/600V Max. 200kA
Dimensions (WxHxD) NEMA 1: 18" x 31" x 13" NEMA 3R, 4, 12: 17.5" x 35" x 11.625"
ASCO Series 300 Series
 
ASCO 300 Series Automatic Transfer Switch NON-SE RATED 2 Pole 1-PH 3-PH 104A NEMA 3R
By PGA LLC AdmiN | |
ASCO Automatic Transfer Switch Manufactured by Schneider Electric.
With an ATS, you are protected 24 hours a day, seven days a week.
When the utility power fails, the ATS automatically starts the generator set and
transfers the load once the generator has reached proper voltage and
frequency. This happens in a matter of seconds after the power failure occurs.
As soon as the utility power has been restored, the ATS will automatically switch the load
back and, after a time delay, shut down the engine generator.
UL 1008
Listed to UL 1008 standard for total system loads for automatic transfer switches.
Meets NFPA 110
Meets NFPA 110 for Emergency and Standby Power Systems and the National Electrical Code Articles 700, 701 and 702.
True Double-Throw Operation
The inherently inter-locked, single solenoid design prevents connections to both
sources at the same time.
Series 300 Group G Controller
Easy-to-navigate 128×64  LCD display with keypad provides LED indicators for switch
position, source availability, not in auto mode, and alert condition.
The controller also includes test and time delay bypass soft keys.
Withstand and Close-On Rating
Maximum of 42kA when used with circuit breakers.
Designed to Fit Anywhere
The ASCO Automatic Transfer Switch, 300 series line represents the most compact design
of automatic power transfer switches in the industry. With space in electrical closets being
at a premium, the use of wall or floor mounted ASCO Transfer Switches assure designers
optimum utilization of space. All transfer switches through 2000 amperes are designed to
be completely front accessible; permitting the enclosures to be installed flush against the
wall while allowing installation of all power cabling and connections from the front of the
switch. Additionally, cable entrance plates are also standard on the 1600 and 2000 amperes
units to install optional side-mounted pull boxes for additional cable bending space.

Additional Information

Amperage 104 Amps
Voltage Output 115-600V
Frame D
Current Limiting Fuses 480/600V Max. 200kA
Dimensions (WxHxD) NEMA 1: 18" x 31" x 13" NEMA 3R, 4, 12: 17.5" x 35" x 11.625"
ASCO Series 300 Series
 
ASCO 300 Series Automatic Transfer Switch NON-SE RATED 2 Pole 1-PH 3-PH 30A NEMA 1
By PGA LLC AdmiN | |
ASCO Automatic Transfer Switch Manufactured by Schneider Electric.
With an ATS, you are protected 24 hours a day, seven days a week.
When the utility power fails, the ATS automatically starts the generator set and
transfers the load once the generator has reached proper voltage and
frequency. This happens in a matter of seconds after the power failure occurs.
As soon as the utility power has been restored, the ATS will automatically switch the load
back and, after a time delay, shut down the engine generator.
UL 1008
Listed to UL 1008 standard for total system loads for automatic transfer switches.
Meets NFPA 110
Meets NFPA 110 for Emergency and Standby Power Systems and the National Electrical Code Articles 700, 701 and 702.
True Double-Throw Operation
The inherently inter-locked, single solenoid design prevents connections to both
sources at the same time.
Series 300 Group G Controller
Easy-to-navigate 128×64  LCD display with keypad provides LED indicators for switch
position, source availability, not in auto mode, and alert condition.
The controller also includes test and time delay bypass soft keys.
Withstand and Close-On Rating
Maximum of 22kA when used with circuit breakers.
Designed to Fit Anywhere
The ASCO Automatic Transfer Switch, 300 series line represents the most compact design
of automatic power transfer switches in the industry. With space in electrical closets being
at a premium, the use of wall or floor mounted ASCO Transfer Switches assure designers
optimum utilization of space. All transfer switches through 2000 amperes are designed to
be completely front accessible; permitting the enclosures to be installed flush against the
wall while allowing installation of all power cabling and connections from the front of the
switch. Additionally, cable entrance plates are also standard on the 1600 and 2000 amperes
units to install optional side-mounted pull boxes for additional cable bending space.

Additional Information

Amperage 30 Amps
Voltage Output 115-480V
Frame D
Current Limiting Fuses 240/480 Max. 100kA
Dimensions (WxHxD) NEMA 1: 18" x 31" x 13" NEMA 3R, 4, 12: 17.5" x 35" x 11.625"
 
ASCO 300 Series Automatic Transfer Switch NON-SE RATED 2 Pole 1-PH 3-PH 30A NEMA 3R
By PGA LLC AdmiN | |
ASCO Automatic Transfer Switch Manufactured by Schneider Electric.
With an ATS, you are protected 24 hours a day, seven days a week.
When the utility power fails, the ATS automatically starts the generator set and
transfers the load once the generator has reached proper voltage and
frequency. This happens in a matter of seconds after the power failure occurs.
As soon as the utility power has been restored, the ATS will automatically switch the load
back and, after a time delay, shut down the engine generator.
UL 1008
Listed to UL 1008 standard for total system loads for automatic transfer switches.
Meets NFPA 110
Meets NFPA 110 for Emergency and Standby Power Systems and the National Electrical Code Articles 700, 701 and 702.
True Double-Throw Operation
The inherently inter-locked, single solenoid design prevents connections to both
sources at the same time.
Series 300 Group G Controller
Easy-to-navigate 128×64  LCD display with keypad provides LED indicators for switch
position, source availability, not in auto mode, and alert condition.
The controller also includes test and time delay bypass soft keys.
Withstand and Close-On Rating
Maximum of 22kA when used with circuit breakers.
Designed to Fit Anywhere
The ASCO Automatic Transfer Switch, 300 series line represents the most compact design
of automatic power transfer switches in the industry. With space in electrical closets being
at a premium, the use of wall or floor mounted ASCO Transfer Switches assure designers
optimum utilization of space. All transfer switches through 2000 amperes are designed to
be completely front accessible; permitting the enclosures to be installed flush against the
wall while allowing installation of all power cabling and connections from the front of the
switch. Additionally, cable entrance plates are also standard on the 1600 and 2000 amperes
units to install optional side-mounted pull boxes for additional cable bending space.

Additional Information

Amperage 30 Amps
Voltage Output 115-480V
Frame D
Current Limiting Fuses 240/480 Max. 100kA
Dimensions (WxHxD) NEMA 1: 18" x 31" x 13" NEMA 3R, 4, 12: 17.5" x 35" x 11.625"
 
ASCO 300 Series Automatic Transfer Switch NON-SE RATED 2 Pole 1-PH 3-PH 70A NEMA 1
By PGA LLC AdmiN | |
ASCO Automatic Transfer Switch Manufactured by Schneider Electric.
With an ATS, you are protected 24 hours a day, seven days a week.
When the utility power fails, the ATS automatically starts the generator set and
transfers the load once the generator has reached proper voltage and
frequency. This happens in a matter of seconds after the power failure occurs.
As soon as the utility power has been restored, the ATS will automatically switch the load
back and, after a time delay, shut down the engine generator.
UL 1008
Listed to UL 1008 standard for total system loads for automatic transfer switches.
Meets NFPA 110
Meets NFPA 110 for Emergency and Standby Power Systems and the National Electrical Code Articles 700, 701 and 702.
True Double-Throw Operation
The inherently inter-locked, single solenoid design prevents connections to both
sources at the same time.
Series 300 Group G Controller
Easy-to-navigate 128×64  LCD display with keypad provides LED indicators for switch
position, source availability, not in auto mode, and alert condition.
The controller also includes test and time delay bypass soft keys.
Withstand and Close-On Rating
Maximum of 42kA when used with circuit breakers.
Designed to Fit Anywhere
The ASCO Automatic Transfer Switch, 300 series line represents the most compact design
of automatic power transfer switches in the industry. With space in electrical closets being
at a premium, the use of wall or floor mounted ASCO Transfer Switches assure designers
optimum utilization of space. All transfer switches through 2000 amperes are designed to
be completely front accessible; permitting the enclosures to be installed flush against the
wall while allowing installation of all power cabling and connections from the front of the
switch. Additionally, cable entrance plates are also standard on the 1600 and 2000 amperes
units to install optional side-mounted pull boxes for additional cable bending space.

Additional Information

Amperage 70 Amps
Voltage Output 115-600V
Frame D
Current Limit Fuses 480/600V Max. 200kA
Dimensions (WxHxD) NEMA 1: 18" x 31" x 13" NEMA 3R, 4, 12: 17.5" x 35" x 11.625"
ASCO Series 300 Series
 
ASCO 300 Series Automatic Transfer Switch NON-SE RATED 2 Pole 1-PH 3-PH 70A NEMA 3R
By PGA LLC AdmiN | |
ASCO Automatic Transfer Switch Manufactured by Schneider Electric.
With an ATS, you are protected 24 hours a day, seven days a week.
When the utility power fails, the ATS automatically starts the generator set and
transfers the load once the generator has reached proper voltage and
frequency. This happens in a matter of seconds after the power failure occurs.
As soon as the utility power has been restored, the ATS will automatically switch the load
back and, after a time delay, shut down the engine generator.
UL 1008
Listed to UL 1008 standard for total system loads for automatic transfer switches.
Meets NFPA 110
Meets NFPA 110 for Emergency and Standby Power Systems and the National Electrical Code Articles 700, 701 and 702.
True Double-Throw Operation
The inherently inter-locked, single solenoid design prevents connections to both
sources at the same time.
Series 300 Group G Controller
Easy-to-navigate 128×64  LCD display with keypad provides LED indicators for switch
position, source availability, not in auto mode, and alert condition.
The controller also includes test and time delay bypass soft keys.
Withstand and Close-On Rating
Maximum of 42kA when used with circuit breakers.
Designed to Fit Anywhere
The ASCO Automatic Transfer Switch, 300 series line represents the most compact design
of automatic power transfer switches in the industry. With space in electrical closets being
at a premium, the use of wall or floor mounted ASCO Transfer Switches assure designers
optimum utilization of space. All transfer switches through 2000 amperes are designed to
be completely front accessible; permitting the enclosures to be installed flush against the
wall while allowing installation of all power cabling and connections from the front of the
switch. Additionally, cable entrance plates are also standard on the 1600 and 2000 amperes
units to install optional side-mounted pull boxes for additional cable bending space.

Additional Information

Amperage 70 Amps
Voltage Output 115-600V
Frame D
Current Limit Fuses 480/600V Max. 200kA
Dimensions (WxHxD) NEMA 1: 18" x 31" x 13" NEMA 3R, 4, 12: 17.5" x 35" x 11.625"
ASCO Series 300 Series
 
ASCO 300 Series Automatic Transfer Switch NON-SE RATED 2 Pole 150A NEMA 1
By PGA LLC AdmiN | |
ASCO Automatic Transfer Switch Manufactured by Schneider Electric.
With an ATS, you are protected 24 hours a day, seven days a week.
When the utility power fails, the ATS automatically starts the generator set and
transfers the load once the generator has reached proper voltage and
frequency. This happens in a matter of seconds after the power failure occurs.
As soon as the utility power has been restored, the ATS will automatically switch the load
back and, after a time delay, shut down the engine generator.
UL 1008
Listed to UL 1008 standard for total system loads for automatic transfer switches.
Meets NFPA 110
Meets NFPA 110 for Emergency and Standby Power Systems and the National Electrical Code Articles 700, 701 and 702.
True Double-Throw Operation
The inherently inter-locked, single solenoid design prevents connections to both
sources at the same time.
Series 300 Group G Controller
Easy-to-navigate 128×64  LCD display with keypad provides LED indicators for switch
position, source availability, not in auto mode, and alert condition.
The controller also includes test and time delay bypass soft keys.
Withstand and Close-On Rating
Maximum of 65kA when used with circuit breakers.
Designed to Fit Anywhere
The ASCO Automatic Transfer Switch, 300 series line represents the most compact design
of automatic power transfer switches in the industry. With space in electrical closets being
at a premium, the use of wall or floor mounted ASCO Transfer Switches assure designers
optimum utilization of space. All transfer switches through 2000 amperes are designed to
be completely front accessible; permitting the enclosures to be installed flush against the
wall while allowing installation of all power cabling and connections from the front of the
switch. Additionally, cable entrance plates are also standard on the 1600 and 2000 amperes
units to install optional side-mounted pull boxes for additional cable bending space.

Additional Information

Amperage 150 Amps
Voltage Output 115-600V
Frame D
Current Limiting Fuses 480/600V Max. 200kA
Dimensions (WxHxD) NEMA 1: 18" x 31" x 13" NEMA 3R, 4, 12: 17.5" x 35" x 11.625"
 
ASCO 300 Series Automatic Transfer Switch NON-SE RATED 2 Pole 150A NEMA 3R
By PGA LLC AdmiN | |
ASCO Automatic Transfer Switch Manufactured by Schneider Electric.
With an ATS, you are protected 24 hours a day, seven days a week.
When the utility power fails, the ATS automatically starts the generator set and
transfers the load once the generator has reached proper voltage and
frequency. This happens in a matter of seconds after the power failure occurs.
As soon as the utility power has been restored, the ATS will automatically switch the load
back and, after a time delay, shut down the engine generator.
UL 1008
Listed to UL 1008 standard for total system loads for automatic transfer switches.
Meets NFPA 110
Meets NFPA 110 for Emergency and Standby Power Systems and the National Electrical Code Articles 700, 701 and 702.
True Double-Throw Operation
The inherently inter-locked, single solenoid design prevents connections to both
sources at the same time.
Series 300 Group G Controller
Easy-to-navigate 128×64  LCD display with keypad provides LED indicators for switch
position, source availability, not in auto mode, and alert condition.
The controller also includes test and time delay bypass soft keys.
Withstand and Close-On Rating
Maximum of 65kA when used with circuit breakers.
Designed to Fit Anywhere
The ASCO Automatic Transfer Switch, 300 series line represents the most compact design
of automatic power transfer switches in the industry. With space in electrical closets being
at a premium, the use of wall or floor mounted ASCO Transfer Switches assure designers
optimum utilization of space. All transfer switches through 2000 amperes are designed to
be completely front accessible; permitting the enclosures to be installed flush against the
wall while allowing installation of all power cabling and connections from the front of the
switch. Additionally, cable entrance plates are also standard on the 1600 and 2000 amperes
units to install optional side-mounted pull boxes for additional cable bending space.

Additional Information

Amperage 150 Amps
Voltage Output 115-600V
Frame D
Current Limiting Fuses 480/600V Max. 200kA
Dimensions (WxHxD) NEMA 1: 18" x 31" x 13" NEMA 3R, 4, 12: 17.5" x 35" x 11.625"
 
ASCO 300 Series Automatic Transfer Switch NON-SE RATED 2 Pole 200A NEMA 1
By PGA LLC AdmiN | |
ASCO Automatic Transfer Switch Manufactured by Schneider Electric.
With an ATS, you are protected 24 hours a day, seven days a week.
When the utility power fails, the ATS automatically starts the generator set and
transfers the load once the generator has reached proper voltage and
frequency. This happens in a matter of seconds after the power failure occurs.
As soon as the utility power has been restored, the ATS will automatically switch the load
back and, after a time delay, shut down the engine generator.
UL 1008
Listed to UL 1008 standard for total system loads for automatic transfer switches.
Meets NFPA 110
Meets NFPA 110 for Emergency and Standby Power Systems and the National Electrical Code Articles 700, 701 and 702.
True Double-Throw Operation
The inherently inter-locked, single solenoid design prevents connections to both
sources at the same time.
Series 300 Group G Controller
Easy-to-navigate 128×64 LCD display with keypad provides LED indicators for switch
position, source availability, not in auto mode, and alert condition.
The controller also includes test and time delay bypass soft keys.
Withstand and Close-On Rating
Maximum of 65kA when used with circuit breakers.
Designed to Fit Anywhere
The ASCO Automatic Transfer Switch, 300 series line represents the most compact design
of automatic power transfer switches in the industry. With space in electrical closets being
at a premium, the use of wall or floor mounted ASCO Transfer Switches assure designers
optimum utilization of space. All transfer switches through 2000 amperes are designed to
be completely front accessible; permitting the enclosures to be installed flush against the wall
while allowing installation of all power cabling and connections from the front of the switch.
Additionally, cable entrance plates are also standard on the 1600 and 2000 amperes units to
install optional side-mounted pull boxes for additional cable bending space.

Additional Information

Amperage 200 Amps
Voltage Output 115-480V
Frame D
Current Limiting Fuses 480V Max. 200kA
Dimensions (WxHxD) NEMA 1: 18" x 31" x 13" NEMa 3R, 4, 12: 17.5" x 35" x 11.625"
 
ASCO 300 Series Automatic Transfer Switch NON-SE RATED 2 Pole 200A NEMA 3R
By PGA LLC AdmiN | |
ASCO Automatic Transfer Switch Manufactured by Schneider Electric.
With an ATS, you are protected 24 hours a day, seven days a week.
When the utility power fails, the ATS automatically starts the generator set and
transfers the load once the generator has reached proper voltage and
frequency. This happens in a matter of seconds after the power failure occurs.
As soon as the utility power has been restored, the ATS will automatically switch the load
back and, after a time delay, shut down the engine generator.
UL 1008
Listed to UL 1008 standard for total system loads for automatic transfer switches.
Meets NFPA 110
Meets NFPA 110 for Emergency and Standby Power Systems and the National Electrical Code Articles 700, 701 and 702.
True Double-Throw Operation
The inherently inter-locked, single solenoid design prevents connections to both
sources at the same time.
Series 300 Group G Controller
Easy-to-navigate 128×64 LCD display with keypad provides LED indicators for switch
position, source availability, not in auto mode, and alert condition.
The controller also includes test and time delay bypass soft keys.
Withstand and Close-On Rating
Maximum of 65kA when used with circuit breakers.
Designed to Fit Anywhere
The ASCO Automatic Transfer Switch, 300 series line represents the most compact design
of automatic power transfer switches in the industry. With space in electrical closets being
at a premium, the use of wall or floor mounted ASCO Transfer Switches assure designers
optimum utilization of space. All transfer switches through 2000 amperes are designed to
be completely front accessible; permitting the enclosures to be installed flush against the wall
while allowing installation of all power cabling and connections from the front of the switch.
Additionally, cable entrance plates are also standard on the 1600 and 2000 amperes units to
install optional side-mounted pull boxes for additional cable bending space.

Additional Information

Amperage 200 Amps
Voltage Output 115-480V
Frame D
Current Limiting Fuses 480V Max. 200kA
Dimensions (WxHxD) NEMA 1: 18" x 31" x 13" NEMa 3R, 4, 12: 17.5" x 35" x 11.625"
 
ASCO 300 Series Automatic Transfer Switch NON-SE RATED 3 Pole 1-PH 3-PH 104A NEMA 1
By PGA LLC AdmiN | |
ASCO Automatic Transfer Switch Manufactured by Schneider Electric.
With an ATS, you are protected 24 hours a day, seven days a week.
When the utility power fails, the ATS automatically starts the generator set and
transfers the load once the generator has reached proper voltage and
frequency. This happens in a matter of seconds after the power failure occurs.
As soon as the utility power has been restored, the ATS will automatically switch the load
back and, after a time delay, shut down the engine generator.
UL 1008
Listed to UL 1008 standard for total system loads for automatic transfer switches.
Meets NFPA 110
Meets NFPA 110 for Emergency and Standby Power Systems and the National Electrical Code Articles 700, 701 and 702.
True Double-Throw Operation
The inherently inter-locked, single solenoid design prevents connections to both
sources at the same time.
Series 300 Group G Controller
Easy-to-navigate 128×64 LCD display with keypad provides LED indicators for switch
position, source availability, not in auto mode, and alert condition.
The controller also includes test and time delay bypass soft keys.
Withstand and Close-On Rating
Maximum of 42kA when used with circuit breakers.
Designed to Fit Anywhere
The ASCO Automatic Transfer Switch, 300 series line represents the most compact design
of automatic power transfer switches in the industry. With space in electrical closets being
at a premium, the use of wall or floor mounted ASCO Transfer Switches assure designers
optimum utilization of space. All transfer switches through 2000 amperes are designed to
be completely front accessible; permitting the enclosures to be installed flush against the
wall while allowing installation of all power cabling and connections from the front of the
switch. Additionally, cable entrance plates are also standard on the 1600 and 2000 amperes
units to install optional side-mounted pull boxes for additional cable bending space.

Additional Information

Amperage 104 Amps
Voltage Output 115-600V
Frame D
Current Limiting Fuses 480/600V Max. 200kA
Dimensions (WxHxD) NEMA 1: 18" x 31" x 13" NEMA 3R, 4, 12: 17.5" x 35" x 11.625"
ASCO Series 300 Series